100W ODM SMPS open frame type

600w-kaiguandianyuan

Input Condtion
Model NO.
Output Rail

Output
current

Voltage Accuracy
Regulation
Efficiency
Max Power
Line
Load
90~264V~
47~63Hz
Input current
 1.8A Max.
  KRP-Z106-M
+5V
20A
±5%
±0.5%
 ±1% 
83%
100W
  KRP-Z107-M
+12V
9A
±5%
±0.5%
 ±1% 
81%
100W
  KRP-Z108-M
+15V
7A
±5%
±0.5%
±1%
82%
100W
  KRP-Z109-M
+24V
4.5A
±5%
±0.5%
±1%
83%
100W
  KRP-Z10T-M
+48V
2.1A
±5%
±0.5%
±1%
86%
100W
 
  KRP-Z101-M
+5V
+12V
-12V
10A
3A
0.8A
±5%
±5%
±5%
±0.5%
±0.5%
±0.5%
±1%
±5%
±5%
85%
100W
 
 KRP-Z104-M
+5V
+15V
-15V
10A
2.5A
0.8A
±5%
±5%
±5%
 
±0.5%
±0.5%
±0.5%
 
±1%
±5%
±5%
 
87%
100W
 KRP-Z10H-M
+28V
3.8A
±5%
±0.5%
±1%
89%
100W
 
 KRP-Z10K-M
+5V 
+24V
+12V
2.5A
2.8A
0.7A
±5%
±5%
±5%
 
±0.5%
 
±0.5%
 ±0.5% 
±1%
±5%
±5%
 
88%
100W

100W ODM 24V SMPS open frame type

Features:

  • With built-in PFC

  • Only 1.26-inch height

  • 4.8 watt per cubic inches

  • With medical safety

  • Efficiency between 80% to 90%

  • Operation from 0℃ to 50℃ by convection

Applications:

  • For medical device such as monitors.

  • For peak power required system such as breath machine.

General Specifiations:

  • Input voltage: 90V AC to 264V AC

  • Input frequency: 47Hz to 63Hz

  • Inrush current (cold start at 25℃): <30A at 1150V AC or <60A at 230V AC

  • Effiiency: 83%~86% depends on models at rated load and 115VAC

  • Holdup time: 20 ms typical at rated load and 115VAC, or 230VAC

  • Over-voltage protection: latch off

  • Short-circuit protection: auto recovery

  • Over load protection: auto recovery

  • Remote sense compensates for 0.5V max.load drop

  • Earth leakage: 250uA max. at 240VAC

  • Operating temperature: 0℃ to 50℃ convection derating: 2.5%/℃ > 50℃

  • Cooling: free air convection for 100W with 18CFM forced air flow for 130W

  • Storage temperature: -20℃ to +85℃

EMI:

  • FCC class "B"

  • EN55022 "B", EN55011 "B"

  • Harmonics: EN61000-3-2 class D

EMS:

  • EN61000-4-2, -3, -4, -5, -6, -8, -11

Safety:

  • UL 60601-1

  • CSA C22.2 No. 601.1-M90

  • EN 60950-1, EN 60601-1

  • IEC 60601-1: 1988 +A1+A2 (2nd)

  • IEC 60601-1: 2005 (3rd)

Notes:

1. Dimensions shown in mm (inch) as left. Tolerance: ±0.4mm

2. Size:  

  • 2.1 KRP-Z106-M, Z107-M, Z108-M, Z109-M, Z10T-M, Z10H-M : 5"(127.0mm) x 3"(76.2mm) x 1.18"(30mm)

  • 2.2 KRP-Z101-M, Z104-M, Z10K-M : 5"(127.0mm) x 3"(76.2mm)x 1.26"(32mm)

3. Packing

  • Net weight: 290 g approx./unit

  • Gross weight: 12.5 kg approx./carton, 36 units/carton

  • Carton size: 339 (L) x 339 (W) x 327 (H)

4. Connectors:

  • AC input: Molex 5277-02A or equivalent

  • DC output: Molex 5273 or equivalent

  • Remote sense: Molex 5045-02A or equivalent (for KRP-Z10X-M, X=6, 7, 8, 9, H, T)

  • Fan cutput: Molex 5045-02A or equivalent (for KRP-Z10X-M, X=1, 4, K)

certification-dd