Technical parameters
driver solution for your power unstable troubleProduct characteristics
Super features: Wide voltage input 80V-380V, small harmonics, high stability and reliability of high demand products, with over-voltage over-current short circuit protection, automatic recovery function, over-temperature protection and multiple protection features. Efficiency reaches 85%, power factor up to 0.99, small standby power consumption and truly achieves efficient energy-saving, work stable under -10℃ to +50℃ for 50,000Hours at least. Lighting surge withstand 6KV or above. Intelligent control: time control, temperature control, PWM control carrier. Products achieve modular, standardized, easy to install and maintain. All products designed according with EN55022 / EN61000-3-2 / EN60950 / UL1950 and ROSH compliance.
- Universal Input: 100~240VAC 50~60Hz
- Protections: Short circuit/ Overload/ Over temperature
- O/P: High accuracy, low noise; hold up time≥20mS
- Cooling by free air convection; Auto recovery;
- Operation temperature: 0℃~+40℃;
- 100% full load burn-in test for 8 hours
- High Efficiency, high reliability;
- Built-in Class B EMI Filter
- Long life of 50,000Hours, 2 years warranty
- Compliance to EN61347-2-13 /IEC61347-2-13 /UL8750
Input Condition | Part Number | Output Voltage(DC) | Output Current | Voltage Tolerance | Regulation | Efficiency | Power Max. | |
Line | Load | |||||||
90~264V~ 47~63Hz Input Current 0.45A Max. | JRL-30V-12 | 12V | 2.5A | ±5% | 1% | 5% | 85% | 30W |
JRL-30V-24 | 24V | 1.2A | ±5% | 1% | 5% | 86% | 30W | |
JRL-30V-36 | 36V | 0.8A | ±5% | 1% | 5% | 87% | 30W | |
JRL-30V-42 | 42V | 0.7A | ±4% | 1% | 5% | 87% | 30W | |
JRL-30V-48 | 48V | 0.6A | ±4% | 1% | 5% | 87% | 30W | |
JRL-30V-54 | 54V | 0.5A | ±4% | 1% | 5% | 87% | 30W |