Input Condtion | Model NO. | Output Rail | Output current | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1.0A Max. | KRO-15-5B | | | | | | 75% | 15W | KRO-15-9B | +9V | 1.6A | ±5% | ±1% | ±5% | 75% | 15W | KRO-15-12B | +12V | 1.2A | ±5% | ±1% | ±5% | 75% | 15W | KRO-15-24B | +15V | 1.0A | ±5% | ±1% | ±5% | 75% | 15W |
15W Customized Power Supply ODM Power Supply: Application: Features: Input voltage: 90VAC to 264VAC Input frequency: 47Hz to 63Hz Short circuit protection , OVP , OCP Ligh weigh, compact design Reliable MTBF > 50000h, 2 years warranty
Environment specification: Operation temperature: 0-40℃ Storage temperature: -10-70℃ Humidity: 5 to 95% non-condensing
Mechanical specifications Electrical specifications: 

|
See More...
|

Input Condtion | Model NO. | Output Rail | Output current | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1.0A Max. | KRO-30-5B | | | | | | 75% | 30W | KRO-30-9B | +12V | 2.5A | ±5% | ±1% | ±5% | 75% | 30W | KRO-30-12B | +15V | 2.0A | ±5% | ±1% | ±5% | 75% | 30W | KRO-30-24B | +24V | 1.25A | ±5% | ±1% | ±5% | 75% | 30W |
30W Customized Power Supply Application: Features: Input voltage: 90VAC to 264VAC Input frequency: 47Hz to 63Hz Short circuit protection , OVP , OCP Ligh weigh, compact design Reliable MTBF > 50000h, 2 years warranty
Environment specification: Operation temperature: 0-40℃ Storage temperature: -10-70℃ Humidity: 5 to 95% non-condensing
Mechanical specifications Electrical specifications: 

|
See More...
|

Input Condtion | Model NO. | Output Rail | | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1A Max. | KRP-HF37 KRP-HF37-A | | | | | | 86% 87% | 30W | KRP-HF38 KRP-HF38-A | +15V | 2A | ±5% | ±0.5% | ±1% | 86% 78% | 30W | KRP-HF39 KRP-HF39-A | +24V | 1.25A | ±5% | ±0.5% | ±1% | 86% 78% | 30W | KRP-HF3T KRP-HF3T-A | +48V | 0.63A | ±5% | ±0.5% | ±1% | 86% 83% | 30W | 30W Medical Power Supply PCBA TypeFeatures: Design for BF application Meet 2 X MOPP and Contact Leakage < 100uA Safety Class II & EMI Class B Follow ErP Directive of EU High mechanical torque start-up -40℃ to +70℃ operating temperature 5,000m operation altitude Convection cooling for rated load Forced air for max. load
General Specifiations: Input voltage: 90V AC to 264V AC Input frequency: 47Hz to 63Hz Inrush current (cold start at 25℃): <40A at 1150V AC or <80A at 230V AC Hold up time: 16ms Over-voltage protection: latch off Short-circuit protection: auto recovery Over load protection: auto recovery Operating temperature: -40℃ to 70℃ derating: 2.5%/℃>50℃ Storage temperature: -40℃ to +85℃
EMI: EMS: EN61000-4-2, -3, -4, -5,-6,-8,-11
Safety: UL/CSA/IEC60950-1,2nd edition ANSI/AMMI/CSA/IEC60601-1,3nd edition CB report, CE mark, RM report/file
Notes: 1. Size: 1.57" (40.0mm) x 2.76"(70.0mm) x 0.93"(23.5mm) 2. Mounting Hole: 33 x 64 (mm) 3. Connectors: AC input: JST B2P3-VH or Molex 5277-02A or equivalent DC output: JST B2P-VH or Molex 5273-02A or equivalent Output Pin assignment:1-Vo 2-GND
4. Packing: Net weight: 61 g approx./ unit Gross weight: 12 kg approx./carton, 150 units/carton Carton size: 412 (L) x 327 (W) x 283 (H)

|
See More...
|

Input Condtion | Model NO. | Output Rail | | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1.0A Max. | KRP-G047 KRP-G047-M | | | | | | 84% | 40W | KRP-G048 KRP-G048-M | +15V | 2.66A | ±5% | ±0.5% | ±1% | 85% | 40W | KRP-G045 KRP-G045-M | +18V | 2.22A | ±5% | ±0.5% | ±1% | 86% | 40W | KRP-G049 KRP-G049-M | +24V | 1.66A | ±5% | ±0.5% | ±1% | 86% | 40W | KRP-G04G KRP-G04G-M | +28V | 1.42A | ±5% | ±0.5% | ±1% | 86% | 40W | KRP-G04J KRP-G04J-M | +36V | 1.11A | ±5% | ±0.5% | ±1% | 85% | 40W | KRP-G04T KRP-G04T-M | +48V | 0.83A | ±5% | ±0.5% | ±1% | 86% | 40W |
40W Customized Power Supply Features: Only 0.91 inch height 7.3 Watt per cubic inch With ITE & medical safety Efficiency between 84% to 86% Operation from -20℃ to 70℃ by convection Compatible to Class I/ II safety & EMC
Applications: For dental, laboratory products, pumps, monitors, sleep apnea devices and many other uses.
General Specifiations: Input voltage: 90V AC to 264V AC Input frequency: 47Hz to 63Hz Inrush current (cold start at 25℃): <30A at 1150V AC or <60A at 230V AC Effiiency: 84%-86% depends on models Hold up time: >18ms typical at rated load and 115V AC Over-voltage protection: latch off Short-circuit protection: auto recovery Over load protection: auto recovery Operating temperature: -20℃ to 70℃ derating: 2.5%/℃>50℃ Cooling: 40W free air convection Storage temperature: -40℃ to +85℃
EMI: EMS: EN61000-4-2, -3, -4, -5,-6,-8,-11
Safety: UL/CSA/IEC60950-1,2nd edition ANSI/AMMI/CSA/IEC60601-1,3nd edition
Notes: 1. Size: 2" (50.8mm) x 3"(76.2mm) x 0.91"(23.1mm) 2. Mounting Hole: 44.5 x 69.9 (mm) 3. Connectors: AC input: Molex 5277-02A or equivalent DC output: Molex 5273-04A or equivalent Output Pin assignment:1-Vo 2-Vo 3-GND 4-GND
4. Packing: Net weight: 88.5g approx./ unit Gross weight: 11.4 kg approx./carton, 100 units/carton Carton size: 412 (L) x 382 (W) x 225 (H)

|
See More...
|

Input Condtion | Model NO. | Output Rail | Output current | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1.2A Max. | KRO-45-9B | | | | | | 84% | 45W | KRO-45-12B | +12V | 3.75A | ±5% | ±1% | ±5% | 84% | 45W | KRO-45-15B | +15V | 3.0A | ±5% | ±1% | ±5% | 84% | 45W | KRO-45-24B | +24V | 1.875A | ±5% | ±1% | ±5% | 84% | 45W | 45W ODM SMPS Open frame typeApplication: Features: Input voltage: 90VAC to 264VAC Input frequency: 47Hz to 63Hz Short circuit protection , OVP , OCP Ligh weigh, compact design Reliable MTBF > 50000h, 2 years warranty
Environment specification: Operation temperature: 0-40℃ Storage temperature: -10-70℃ Humidity: 5 to 95% non-condensing
Mechanical specifications Electrical specifications: 

|
See More...
|

Input Condtion | Model NO. | Output Rail | | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1.5A Max. | KRP-Z056 | | | | | | 83% | 55W | KRP-Z057 | +12V | 4.6A | ±5% | ±0.5% | ±0.5% | 85% | 55W | KRP-Z058 | +15V | 3.7A | ±5% | ±0.5% | ±0.5% | 85% | 55W | KRP-Z059 | +24V | 2.3A | ±5% | ±0.5% | ±0.5% | 86% | 55W | KRP-Z05T | +48V | 1.15A | ±5% | ±0.5% | ±0.5% | 86% | 55W |
55W Medical Grade Power Supply Solution Features: Only 1.1-inch height With ITE & Medical safety Efficiency between 83% to 86% Operation from 0℃ to 60℃ by convection
Applications: For dental, laboratory products, pumps, monitors, sleep apnea devices and many other uses.
General Specifiations: Input voltage: 90V AC to 264V AC Input frequency: 47Hz to 63Hz Inrush current (cold start at 25℃): <30A at 1150V AC or <60A at 230V AC Effiiency: 83%~86% depends on models at rated load and 115VAC Holdup time: 14ms typical at rated load and 115VAC Over-voltage protection: latch off Short-circuit protection: auto recovery Over load protection: auto recovery Operating temperature: 0℃ to 60℃ convection derating: 2.5%/℃ > 50℃ Cooling: free air convection Storage temperature: -40℃ to +85℃
EMI: EMS: EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety: Notes: 1. Dimensions shown in mm (inch) as left. Tolerance: ±1mm (excluding cable) 2. Size: 4"(101.6mm) x 2"(50.8mm) x 1.1"(28.5mm) 3. Packing Net weight: 140 g approx./unit Gross weight: 13.5 kg approx./carton, 80 units/carton Carton size: 382 (L) x 374 (W) x 277 (H)
4. Connectors: AC input: JST B2P3-VH or equivalent DC output: JST B4P-VH or equivalent for single output , JST B7P-VH or equivalent for multiple outputs

|
See More...
|

Input Condtion | Model NO. | Output Rail | | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1.5A Max. | KRP-Z061 | | | | | | 82% | 65W | KRP-Z06D | +3.3V +5V +12V | 4.5A 3A 0.7A | ±5% ±5% ±5% | ±1% ±1% ±1% | ±3% ±3% ±5% | 80% | 65W | KRP-Z063 | +5V +12V | 3A 3A | ±5% ±5% | ±1% ±1% | ±3% ±3% | 82% | 65W | KRP-Z06A | +5V +24V | 4A 1.5A | ±5% ±5% | ±1% ±1% | ±3% ±3% | 83% | 65W | KRP-Z066-1 | +5V | 12A | ±5% | ±0.5% | ±0.5% | 85% | 65W | KRP-Z067 | +12V +5V | 4.8A 0.5A | ±5% ±5% | ±1% ±1% | ±1% ±1% | 84% | 65W | KRP-Z067-1 | +12V | 5A | ±5% | ±1% | ±1% | 85% | 65W | KRP-Z068 | +15V +5V | 3.8A 0.5A | ±5% ±5% | ±1% ±1% | ±1% ±1% | 85% | 65W | KRP-Z068-1 | +15V | 4.3A | ±5% | ±1% | ±1% | 85% | 65W | KRP-Z069 | +24V +5V | 2.4A 0.5A | ±5% ±5% | ±1% ±1% | ±1% ±1% | 85% | 65W | KRP-Z069-1 | +24V | 2.7A | ±5% | ±1% | ±1% | 85% | 65W | KRP-Z06T | +48V | 1.35A | ±5% | ±0.5% | ±0.5% | 87% | 65W |
65W ITE Power Supply Design Features: Only 1.18 inch height With ITE & Medical safety Efficiency between 77% to 87% Operation from 0℃ to 70℃ by convection
Applications: For dental, laboratory products, pumps, monitors, sleep apnea devices and many other uses.
General Specifiations: Input voltage: 90V AC to 264V AC Input frequency: 47Hz to 63Hz Inrush current (cold start at 25℃): <30A at 1150V AC or <60A at 230V AC Effiiency: 83%~86% depends on models at rated load and 115VAC Holdup time: 15ms typical at rated load and 115VAC, or 230VAC Over-voltage protection: latch off Short-circuit protection: auto recovery Over load protection: auto recovery Operating temperature: 0℃ to 70℃ convection derating: 2.5%/℃ > 50℃ Cooling: free air convection Storage temperature: -40℃ to +85℃
EMI: FCC class "B" EN55022 "B", EN55011 "B"
EMS: EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety: Notes: 1. Dimensions shown in mm (inch) as left. Tolerance: ±1mm (excluding cable) 2. Size: 2"(50.8mm) x 4"(101.6mm) x 1.18"(30mm) 3. Packing Net weight: 140 g approx./unit Gross weight: 13.5 kg approx./carton, 80 units/carton Carton size: 382 (L) x 374 (W) x 277 (H)
4. Connectors: AC input: JST B2P3-VH or equivalent DC output: JST B4P-VH or equivalent for single output , JST B7P-VH or equivalent for multiple outputs
5. Output Pin assignment: PIN NO. 1 2 3 4 5 6 7 KRP-Z061 -12V +5V +5V GND GND +12V +12V KRP-Z06D +12V +5V +5V GND GND +3.3V +3.3V KRP-Z063 NC +5V +5V GND GND +12V +12V KRP-Z06A NC +5V +5V GND GND +24V +24V ...

|
See More...
|

Input Condtion | Model NO. | Output Rail | | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 1A Max. | KRP-HF67 KRP-HF67-A | | | | | | 87% 82% | 60W | KRP-HF68 KRP-HF68-A | +15V | 4A | ±5% | ±0.5% | ±1% | 87% 82% | 60W | KRP-HF69 KRP-HF69-A | +24V | 2.5A | ±5% | ±0.5% | ±1% | 87% 82% | 60W | KRP-HF6T KRP-HF6T-A | +48V | 1.25A | ±5% | ±0.5% | ±1% | 87% 83% | 60W |
Customized 60W Medical Power Supply Features: Design for BF application Meet 2 X MOPP and Contact Leakage < 100uA Safety Class II & EMI Class B Follow ErP Directive of EU High mechanical torque start-up -40℃ to +70℃ operating temperature 5,000m operation altitude Convection cooling for rated load Forced air for max. load
General Specifiations: Input voltage: 90V AC to 264V AC Input frequency: 47Hz to 63Hz Inrush current (cold start at 25℃): <40A at 1150V AC or <80A at 230V AC Hold up time: 16ms Over-voltage protection: latch off Short-circuit protection: auto recovery Over load protection: auto recovery Operating temperature: -40℃ to 70℃ derating: 2.5%/℃>50℃ Storage temperature: -40℃ to +85℃
EMI: EMS: EN61000-4-2, -3, -4, -5,-6,-8,-11
Safety: UL/CSA/IEC60950-1,2nd edition ANSI/AMMI/CSA/IEC60601-1,3nd edition CB report, CE mark, RM report/file
Notes:
1. Size: 2" (50.8mm) x 3.17"(80.5mm) x 0.95"(24.0mm) 2. Mounting Hole: 44.5 x 69.9 (mm) 3. Connectors: AC input: JST B2P3-VH or equivalent DC output: JST B4P-VH or equivalent Output Pin assignment:1-Vo 2-Vo 3-GND 4-GND
4. Packing: Net weight: 114 g approx./ unit Gross weight: 14 kg approx./carton, 100 units/carton Carton size: 437 (L) x 402 (W) x 240 (H)

|
See More...
|

Input Condtion | Model NO. | Output Rail | | Voltage Accuracy | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 2A Max. | KRP-Z081 | | | | | | 84% | 85W | KRP-Z083 | +5V +12V | 6A 4A | ±5% ±5% | ±1% ±1% | ±1% ±1% | 84% | 85W | KRP-Z08F | +5V +24V +12V | 6A 2A 0.5A | ±5% ±5% ±5% | ±1% ±1% ±1% | ±1% ±1% ±1% | 85% | 85W | KRP-Z086 | +5V | 15A | ±5% | ±1% | ±1% | 81% | 85W | KRP-Z087 | +12V +5V | 6.5A 0.5A | ±5% ±5% | ±1% ±1% | ±1% ±1% | 82% | 85W | KRP-Z087-1 | +12V | 7A | ±5% | ±1% | ±1% | 83% | 85W | KRP-Z089 | +24V +5V | 3.6A 0.5A | ±5% ±5% | ±1% ±1% | ±1% ±1% | 85% | 85W | KRP-Z089-1 | +24V | 3.75A | ±5% | ±1% | ±1% | 86% | 85W | KRP-Z08T | +48V | 1.88A | ±5% | ±1% | ±1% | 87% | 85W |
80W Medical Power Supply Customized Features: Only 1.18 inch height With ITE & Medical safety Efficiency between 81% to 87% Operation from 0℃ to 70℃ by convection
Applications: For dental, laboratory products, pumps, monitors, sleep apnea devices and many other uses.
General Specifiations: Input voltage: 90V AC to 264V AC Input frequency: 47Hz to 63Hz Inrush current (cold start at 25℃): <30A at 1150V AC or <60A at 230V AC Effiiency: 83%~86% depends on models at rated load and 115VAC Holdup time: 14ms typical at rated load and 115VAC Over-voltage protection: latch off Short-circuit protection: auto recovery Over load protection: auto recovery Operating temperature: 0℃ to 70℃ convection derating: 2.5%/℃ > 50℃ Cooling: free air convection Storage temperature: -40℃ to +85℃ EMI: FCC class "B" EN55022 "B", EN55011 "B" EMS: EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety: Notes: 1. Dimensions shown in mm (inch) as left. Tolerance: ±1mm (excluding cable) 2. Size: 2.5"(63.5mm) x 4.5"(114.3mm) x 1.18"(30mm) 3. Packing Net weight: 235 g approx./unit Gross weight: 16.5 kg approx./carton, 60 units/carton Carton size: 447 (L) x 300 (W) x 301 (H)
4. Connectors: 5. Output Pin assignment: 
|
See More...
|
|
|