
Input | Part No. | Output Volt(DC) | Output Current | Voltage Precision | Regulation | Efficiency | Output Power | Linear | Load | 90~264V~ 47~63Hz Input current 0.15A Max. | KRA-0503-3 | 3.0V | 1.0A | ±5% | 1% | 5% | 74% | 3W | KRA-0505-3 | 5.0V | 1.0A | ±5% | 1% | 5% | 75% | 5W | KRA-0508-3 | 8.0V | 0.7A | ±5% | 1% | 5% | 78% | 5.6W | KRA-0512-3 | 12.0V | 0.5A | ±5% | 1% | 5% | 78% | 6.0W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC-DC power adpater 6W series Output Voltage: 3 - 12VDC; Output Power: 6W Max. FeaturesAC-DC switching power adapter Product characteristics Wide voltage input 100V-240V, small harmonics, high stability and reliability of high demand products, with over-voltage over-current short circuit protection, automatic recovery function, over-temperature protection and multiple protection features. 62368 power adapter efficiency reaches 76%, small standby power consumption and truly achieves efficient energy-saving, work stable under 0℃ to +40℃ for 50,000Hours at least. Lighting surge withstand 6KV or above. Poducts achieve modular, standardized, easy to install and maintain. All products designed according with EN55022 / EN61000-3-2 / EN60950 / UL62368 and ROSH compliance. Universal Input: 100~240VAC 50~60Hz Protections: Short circuit/ Overload/ Over temperature O/P: High accuracy, low noise; hold up time≥20mS Cooling by free air convection; Auto recovery; Operation temperature: 0℃~+40℃; 100% full load burn-in test for 8 hours High Efficiency, high reliability; Efficiency Level VI Long life of 50,000Hours, 2 years warranty Compliance to EN60950 / IE60950 / 62368/61558

|
See More...
|

Input | Part No. | Output Volt(DC) | Output Current | Voltage Precision | Regulation | Efficiency | Output Power | Linear | Load | 90~264V~ 47~63Hz Input Current 0.15A Max. | KRA-050A-1 | 5.0V | 1.0A | ±5% | 1% | 5% | 75% | 5W | KRA-050A-2 | 6.0V | 0.8A | ±5% | 1% | 5% | 76% | 4.8W | KRA-050A-3 | 9.0V | 0.6A | ±5% | 1% | 5% | 77% | 5.4W | KRA-050A-4 | 12V | 0.5A | ±5% | 1% | 5% | 77% | 6W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nes Style power adapter:New power adapter:Inpu voltage ranget: AC 100V~240V; Input frequency: 47~63 Hz; In rush current:: Max. 50A @ 230V Cold start Short circut protection: long term/auto recovery; OVC protection: 110%~150% of rated output Hi-pot: input to output 3.0KV/60s@3mA Operation temperature: 0~50°C@100%, -10°C@80%, 60°C@60% Enery standard: ERP, energy start; Safety: IEC60950 EMC standard: EN55022 class B,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Approval: CE; Rosh compliance Dimensions: 55×43×32(mm)

|
See More...
|

Input | Part No. | Output Voltage(DC) | Output Current | Voltage Precision | Regultion | Efficiency | Power Max. | Linear | Load | 90~264V~ 47~63Hz Input Current 0.15A Max. | KRA1-0603-3 | 3.0V | 1.0A | ±5% | 1% | 5% | 69.6% | 3W | KRA1-0605-3 | 5.0V | 1.2A | ±5% | 1% | 5% | 75.0% | 6W | KRA1-0609-3 | 9.0V | 0.67A | ±5% | 1% | 5% | 78.8% | 6W | KRA1-0612-3 | 12.0V | 0.5A | ±5% | 1% | 5% | 78.8% | 6W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Efficiency Level VI AC-DC Power Adapter 6W SeriesOutput Voltage: 3 - 12VDC; Output Power: 6W Maximum Product Features: Wide voltage input 100V-240V, small harmonics, high stability and reliability of high demand products, with over-voltage over-current short circuit protection, automatic recovery function, over-temperature protection and multiple protection features. Efficiency reaches 78%, standby power<0.1W. Small standby power consumption and truly achieves efficient energy-saving, work stable under 0℃ to +40℃ for 50,000Hours at least. Products achieve modular, standardized, easy to install and maintain. All products designed according with EN55022 / EN61000-3-2 / EN60950 / UL130 and ROSH compliance Universal Input: 100~240VAC 50~60Hz Protections: Short circuit/ Overload/ Over temperature O/P: High accuracy, low noise; hold up time≥20mS Cooling by free air convection; Auto recovery; Operation temperature: 0℃~+40℃; 100% full load burn-in test for 8 hours High Efficiency, high reliability; Built-in Class B EMI Filter Long life of 50,000Hours, 2 years warranty Compliance to EN60950 / IE60950 / EN55022 Efficiency level: VI

|
See More...
|

Input | Part No. | Outport Voltage(DC) | Output current | Voltage precision | Regulation | Efficiency | Max Power | Line | Load | 90~264V~ 47~63Hz Input current 0.5A Max. | SAW12-050-2400U | 5.0V | 2.40A | ±5% | 1% | 5% | 73% | 12W | SAW12-090-1200U | 9.0V | 1.2A | ±5% | 1% | 5% | 75% | 12W | SAW12-120-1000U | 12.0V | 1.0A | ±5% | 1% | 5% | 75% | 12W | SAW12-240-0500U | 24.0V | 0.5A | ±5% | 1% | 5% | 75% | 12W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12W US plug power adapter futures:Input: AC 90V~264V; DC Input: DC 125V~370V Input Frequency: 47~63 Hz; Inrush current: Max. 30A @ 230V Cold start Short Current protection: Long term/ Auto recover; Overload protection: 110%~150% of rated ouput Hi-pot: input to output 3.0KV/60s@3mA Operation temperature: 0~50°C@100%, -10°C@80%, 60°C@60% Efficiency level: CEC, DOE; afety standard: IEC60950 EMC Standard: EN55022 class B,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Certification: UL FCC,CE,GS,SAA,PSE; Rohs Complance Dimensions: 59×48.54×25.5(mm)



|
See More...
|

Input
|
Part No.
|
Output Voltage(DC)
|
Output current
|
Voltage precision
|
Regulation
|
Efficiency
|
Max Power
|
Line
|
Load
|
90~264V~
47~63Hz
Input current
0.5A Max.
|
SAW12-050-2400E
|
5.0V
|
2.40A
|
±5%
|
1%
|
5%
|
73%
|
12W
|
SAW12-090-1200E
|
9.0V
|
1.2A
|
±5%
|
1%
|
5%
|
75%
|
12W
|
SAW12-120-1000E
|
12.0V
|
1.0A
|
±5%
|
1%
|
5%
|
75%
|
12W
|
SAW12-240-0500E
|
24.0V
|
0.5A
|
±5%
|
1%
|
5%
|
75%
|
12W
|
12W EU plug power adapter futures:
- Input: AC 90V~264V; DC Input: DC 125V~370V
- Input Frequency: 47~63 Hz; Inrush current: Max. 30A @ 230V Cold start
- Short Current protection: Long term/ Auto recover; Overload protection: 110%~150% of rated ouput
- Hi-pot: input to output 3.0KV/60s@3mA
- Operation temperature: 0~50°C@100%, -10°C@80%, 60°C@60%
- Efficiency level: CEC, DOE; afety standard: IEC60950
- EMC Standard: EN55022 class B,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
- Certification: UL FCC,CE,GS,SAA,PSE; Rohs Complance
- Dimensions: 59×48.54×25.5(mm)



|
See More...
|

Input
|
Part No.
|
Output Voltage(DC)
|
Output current
|
Voltage precision
|
Regulation
|
Efficiency
|
Max Power
|
Line
|
Load
|
90~264V~
47~63Hz
Input current
0.5A Max.
|
SAW12-050-2400UK
|
5.0V
|
2.40A
|
±5%
|
1%
|
5%
|
73%
|
12W
|
SAW12-090-1200UK
|
9.0V
|
1.2A
|
±5%
|
1%
|
5%
|
75%
|
12W
|
SAW12-120-1000UK
|
12.0V
|
1.0A
|
±5%
|
1%
|
5%
|
75%
|
12W
|
SAW12-240-0500UK
|
24.0V
|
0.5A
|
±5%
|
1%
|
5%
|
75%
|
12W
|
12W UK plug power adapter futures:
- Input: AC 90V~264V; DC Input: DC 125V~370V
- Input Frequency: 47~63 Hz; Inrush current: Max. 30A @ 230V Cold start
- Short Current protection: Long term/ Auto recover; Overload protection: 110%~150% of rated ouput
- Hi-pot: input to output 3.0KV/60s@3mA
- Operation temperature: 0~50°C@100%, -10°C@80%, 60°C@60%
- Efficiency level: CEC, DOE; afety standard: IEC60950
- EMC Standard: EN55022 class B,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
- Certification: UL FCC,CE,GS,SAA,PSE; Rohs Complance
- Dimensions: 59×48.54×25.5(mm)



|
See More...
|

Input | Part No. | Output Voltage(DC) | Output Current | Voltage Precision | Regulation | Eficiency | Power Max. | Linear | Load | 90~264V~ 47~63Hz Input current 0.30A Max. | KRA1-1205-3 | 5.0V | 2.4A | ±5% | 1% | 5% | 80% | 12W | KRA1-1209-3 | 9.0V | 1.3A | ±5% | 1% | 5% | 83% | 12W | KRA1-1212-3 | 12V | 1.0A | ±5% | 1% | 5% | 83% | 12W | KRA1-1224-3 | 24V | 0.5A | ±5% | 1% | 5% | 83% | 12W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Efficiency Leve VI AC-DC adapter 12W Series Ouput Voltage: 5 - 24VDC; Ouput Power: 12W Maximum Product Features: Switching adapter wide voltage input 100V-240V, small harmonics, high stability and reliability of high demand products, with over-voltage over-current short circuit protection, automatic recovery function, over-temperature protection and multiple protection features. AC DC adapter 12v efficiency reaches 83%, standby power <0.1W. Small standby power consumption and truly achieves efficient energy-saving, work stable under 0℃ to +40℃ for 50,000Hours at least. Products achieve modular, standardized, easy to install and maintain. All products designed according with EN55022 / EN61000-3-2 / EN60950 / UL60950 and ROSH compliance. Universal Input: 100~240VAC 50~60Hz Protections: Short circuit/ Overload/ Over temperature O/P: High accuracy, low noise; hold up time≥20mS Cooling by free air convection; Auto recovery; Operation temperature: 0℃~+40℃; 100% full load burn-in test for 8 hours High Efficiency, high reliability; Built-in Class B EMI Filter Long life of 50,000Hours, 2 years warranty Compliance to EN60950 / UL60950 / EN55022 Efficiency Level: VI

|
See More...
|

Input | Part No. | Output Volt(DC) | Output Current | Voltage Precision | Regulation | Efficiency | Output Power | Linear | Load | 90~264V~ 47~63Hz Input Current 0.30A Max. | KRA-1205-1 | 5.0V | 2.0A | ±5% | 1% | 5% | 73% | 10W | KRA-1209-1 | 9.0V | 1.3A | ±5% | 1% | 5% | 78% | 12W | KRA-1212-1 | 12V | 1.0A | ±5% | 1% | 5% | 78% | 12W | KRA-1224-1 | 24V | 0.5A | ±5% | 1% | 5% | 78% | 12W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC-DC power adapter 12W series Output Voltage: 3 - 24VDC; Output Power: 12W Max. FeaturesAC-DC switching power adapter Product characteristics 12W power adapter wide voltage input 100V-240V, small harmonics, high stability and reliability of high demand products, with over-voltage over-current short circuit protection, automatic recovery function, over-temperature protection and multiple protection features. 12volt adapter efficiency reaches 82%, small standby power consumption and truly achieves efficient energy-saving, work stable under 0℃ to +40℃ for 50,000Hours at least. Lighting surge withstand 6KV or above. Products achieve modular, standardized, easy to install and maintain. All products designed according with EN55022 / EN61000-3-2 / EN60950 / UL1950 and ROSH compliance. Universal Input: 100~240VAC 50~60Hz Protections: Short circuit/ Overload/ Over temperature O/P: High accuracy, low noise; hold up time≥20mS Cooling by free air convection; Auto recovery; Operation temperature: 0℃~+40℃; 100% full load burn-in test for 8 hours High Efficiency, high reliability; Built-in Class B EMI Filter Long life of 50,000Hours, 2 years warranty Compliance to EN60950 /IEC60950/ UL60950

|
See More...
|

Input | Part No. | Output Volt(DC) | Output Current | Voltage Precision | Regulation | Efficiency | Output Power | Linear | Load | 90~264V~ 47~63Hz Input Current 0.45A Max. | KRA-18050-2 | 5.0V | 3.0A | ±5% | 1% | 5% | 78% | 15W | KRA-18090-2 | 9.0V | 2.0A | ±5% | 1% | 5% | 81% | 18W | KRA-18120-2 | 12V | 1.5A | ±5% | 1% | 5% | 81% | 18W | KRA-18240-2 | 24V | 0.75A | ±5% | 1% | 5% | 81% | 18W |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wall mounted AC-DC Power adapter 18W Series Output Voltage: 5 - 24VDC; Output Power: 18W Max FeaturesAC-DC switching power adapter Product characteristics 18W european adapter with wide voltage input 100V-240V, small harmonics, high stability and reliability of high demand products, with over-voltage over-current short circuit protection, automatic recovery function, over-temperature protection and multiple protection features. Efficiency reaches 81%, small standby power consumption and truly achieves efficient energy-saving, work stable under 0℃ to +40℃ for 50,000Hours at least. Lighting surge withstand 6KV or above. Intelligent control: temperature control, PWM control carrier. Products achieve modular, standardized, easy to install and maintain. All products designed according with EN55022 / EN61000-3-2 / EN60950 / UL1950 and ROSH compliance. Universal Input: 100~240VAC 50~60Hz Protections: Short circuit/ Overload/ Over temperature O/P: High accuracy, low noise; hold up time≥20mS Cooling by free air convection; Auto recovery; Operation temperature: 0℃~+40℃; 100% full load burn-in test for 8 hours High Efficiency, high reliability; Built-in Class B EMI Filter Long life of 50,000Hours, 2 years warranty Compliance to EN62368 / UL60950 / EN55022

|
See More...
|
|
|